• Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
  • Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
  • Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
  • Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
  • Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
  • Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway

Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway

Gebruik: Automated Industry
Type: Vast
Support Network: Modbustcp to Can Module
Informatie inhoud: Gegevens
Certificaat: CE
Conditie: Nieuw

Neem contact op met de leverancier

Mrs. Ross Lee
Diamant Lid Sinds 2022

Leveranciers met geverifieerde zakelijke licenties

Gecontroleerde Leverancier

Leveranciers beoordeeld door inspectiediensten.

Beoordeling: 5.0/5
Fabrikant/fabriek, Handelsbedrijf

Basis Informatie.

Model NR.
GCAN-205
Function
Can Bus Modbus TCP
Interface
RS485, Ethernet Interface
Can Baud Rate
5kbps~1Mbps
Processor
High Speed 32-Bit Industrial Grade Processor
Support Protocol
Ethernet, ARP, IP, ICMP, UDP, DHCP, DNS, TCP
Secondary Development
Support
Customized
Yes
Dimensions
115mm (L) * 100mm (W) * 22mm (H)
Power Supply
DC+24V
Temp
-40.00ºC~ 85.00ºC
Transportpakket
Carton
Specificatie
113x100x21mm
Handelsmerk
GCAN
Oorsprong
China
Gs-Code
8543709990
Productiecapaciteit
10000

Beschrijving

Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 GatewayGCAN-204 converter has one CAN-Bus interface, one serial interface. The GCAN-204 integrates the Modbus RTU protocol. With the GCAN-204 , user can use the serial bus connect to other equipment (with Modbus RTU protocol) access the CAN-Bus communication interface.GCAN-204 has integrated isolation protection module. Using DIN railway fixed, it can be easier to integrate into the control cabinet.
Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway

Hardware Features
1. High speed 32-bit industrial grade processor
2. Embedded Watchdog timer
3. External voltage (DC+24V, 40mA)
4. Electrostatic discharge (ESD) Immunity level: Contact Discharge±2KV, Air Discharge±15KV
5. Fast transient Burst Impedance Level: ±1KV
6. Surge immunity level: ±1KV
7. Working temperature: -40.00ºC~ 85.00ºC
8. Working humidity: 5%~95%, no condensation
9. Dimensions: 115mm (L) * 100mm (W) * 22mm (H)
10. Customization

CAN Features
1. Integrate one CAN-Bus channel, with terminal connection
2. Support CAN2.0A and CAN2.0B, conform to ISO/DIS11898
3. Support communication baud rate: 5Kbps~1Mbps
4. Electric isolation, insulation level: DC 3000V

Ethernet Features
1. Restore the network connection automatically after disconnecting, can establish a TCP connection.
2. Support protocol including Ethernet, ARP, IP, ICMP, UDP, DHCP, DNS, TCP
3. SOCKET working mode compatibility (TCP Server, TCP Client, UDP, etc), program communication software according to standard
    SOCKET rules
4. Support secondary development, we can provide VB routine or you can look for some another basic programming routine about
Ethernet online

Function & Application
Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 GatewayEthernet and Canbus Connection Modbus TCP Protocol Gcan-205 GatewayEthernet and Canbus Connection Modbus TCP Protocol Gcan-205 GatewayEthernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
Application
Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 GatewayExamples
The user can use the included serial debugging assistant to send Modbus instruction debugging.
Please note: choose "hexadecimal display" and "hexadecimal send" when using the serial debugging assistant.

1 Receive CAN data
For example, configure the Modbus slave address: 1, Modbus register first address: 0x01, CAN: standard frame, frame ID: 0x181, CAN frame data: 
0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08.
User Modbus master sends request frame:

01 03 00 01 00 04 15 C9
GCAN-204 response frame:

01 03 08 02 01 04 03 06 05 08 07 17 C1
Please note that the CRC is calculated by the CRC16 checksum calculator. (With disk)
At this point, the GCAN-204 module has received a data frame with a frame ID of 0x181 from the CAN terminal of other equipment.

3.2 Transmit CAN data
For example, Modbus slave address: 1, Modbus register first address: 0x101 (decimal: 257), function code: 16 (10H), CAN: standard frame, frame ID: 0x201, CAN frame data: 
0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08.

User Modbus master sends request frame:

01 10 01 01 00 04 08 02 01 04 03 06 05 08 07 CB 2E
GCAN-204 response frame:

01 10 01 01 00 04 91 F6
Please note that the CRC is calculated by the CRC16 checksum calculator.
At this point, the CAN terminal of other equipment has received a data frame with a frame ID of 0x201 from the Modbus side of the GCAN-204 module.

Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway
Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway





















 

Stuur uw aanvraag naar deze leverancier

*van:
*naar:
avatar Mrs. Ross Lee
*bericht:

Voer tussen 20 tot 4000 karakters.

Dit is niet wat je zoekt? Plaats Nu het Verzoek tot Scourcing

Zoek vergelijkbare producten op categorie

Startpagina leverancier Producten GCAN Gateway Ethernet and Canbus Connection Modbus TCP Protocol Gcan-205 Gateway

Misschien Vind Je Het Leuk

Bezig met laden...

Product Categorie

Neem contact op met de leverancier

Mrs. Ross Lee
Diamant Lid Sinds 2022

Leveranciers met geverifieerde zakelijke licenties

Gecontroleerde Leverancier

Leveranciers beoordeeld door inspectiediensten.

Beoordeling: 5.0/5
Fabrikant/fabriek, Handelsbedrijf
Maatschappelijk Kapitaal
10000000 RMB
Plantengebied
>2000 Vierkante Meter