Basis Informatie.
Bescherming
Overvoltage Short Circuit Overcurrent Unbalanced
Toepassing
Fire Safety Defence Communication Spaceflight
Classificatie
Verlichting / Vermogen
Standby-tijd
Langwerkende Machine
Output Capacity
Grote Type
Transportpakket
Wooden Case
Oorsprong
Shenzhen Guangdong China
Beschrijving
10kVA-400kVA Power Inverter Online UPS Three Phase Online UPS
modelMZT9830L | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400KVA |
Nominalcapacity(KVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 300 | 400 |
Singe-phase maximum current input(A) | 19 | 29 | 38 | 57 | 76 | 114 | 152 | 189 | 227 | 303 | 379 | 568 | 609 |
Works as well as the principle | On-line power supply,static bypass switch(uninterrupted switch)double conversion technology |
Ac input parameters | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±25% |
Nominal frequency | 50Hz±10%,60Hz±10% |
The voltage harmonic distortion | <10% |
Soft sart | 0-100%5sec |
bypass | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±15% |
Nominal frequency | 50Hz/60Hz±10% |
Inverter/bypass(conversin) | 0ms |
The battery | Number of battery unit | 30knots/12v series |
Nominal battery voltage | 360V |
maximum discharge current(A) | 25 | 38 | 51 | 76 | 101 | 152 | 203 | 253 | 305 | 405 | 550 | 760 | 1015 |
Float chargin voltage | 405V(3 months automatic battery to charge,charge voltarge voltage 435V) |
Charging curret | 1A-5A(according to battery capacity setting) |
inverter | The load power factor | 0.8(0.9optinal) |
Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±1%(The steady-state load),380VAC±3%(The load fluctuation |
Nominal frequency | 50Hz±0.05%,60Hz±0.05%(Battery power) |
Frequency stability:when not in sync | <±0.05% |
When the frequency stability:synchronization | <±5% |
Output waveform | Sine wave |
Total harmonic distortion | Lindar load<2%:The nonlinear load<4% |
Dynamic load voltage transients | <5%(from 0 to 100% more |
Transient recovery time | <10ms(±5%) |
Unbalanced voltage | <±1%(Balance the load voltage),<±3%(Unbalanced load) |
Overload capacity | Overload for ten min later turn the bypass,125% 150%overload lasts1 min after bypass |
The inverter efficiency and load by 100% | 95% |
The system structure | Total efficiency of 100% load | 91%,95%.ECO |
Computer ommunication interface | Rs232,(Rs485.Network remote monitoring software) |
Operating temperature | 0-40ºC |
Relating humidity | 0-90% Without any condensation |
Running high | <1500m(each additional,100meters power fell by 1%, the highest4000meters |
Cooling way | Forced vention(temperature control) |
Noise(db) | <65 |
The body color | black |
The input cable | The bottom/bcak |
Easy to maintain | On/about/in front of the plane can be opened |
Lnput device | Terminal row |
The output device | Terminal row |
Size (D×W×H) | 725×450×1135 | 855×450×1235 | 715×855×1500 | 1100×900×1700 | 1200×1500×1800 | 1300×1800×1800 |
The host weight(kg) | 200 | 250 | 340 | 400 | 480 | 650 | 900 | 1200 | 1300 | 1480 | 2000 | 2100 | 2500 |
Option to | Rs485,weaver board,network management system,battery testing sydstem,lightning protection devices for option |
is required to order |
The characteristics of 3C3 series Three-phase input and output High frequency on-line UPS : Adopted double conversion design, To provide a safe and reliable power supply for the followingsituation: The grid without power, mains voltage too high or too low, instantaneous voltage drop ordamped oscillation, high voltage pulse, voltage fluctuation, surge voltage, harmonic distortion,noise interference, the condition of frequency fluctuations, etc. This product is widely used in sm alland medium sized data center, network management center, enterprise server room and generalindustrial environmentsN+X parallel connection redundancy : The machine has the function of parallel connection, Don'tneed to increase the external accessories, Can achieve the maximum of 6 ~ 8 UPS parallel, The user canbe low cost system expands, N for load required the fewest number of UPS, X represents the numberof redundant , The greater the X system reliability will be higher, Adopts the advanced control strategy,In weaver redundant work condition, the system can support sharing a set of batteries, save theinvestment cost of users,The intelligent battery charge and discharge management: Advanced intelligent charging waysthrough the control of the CPU, according to different environmental conditions, Fixed chargingparameters, Provide the best way of charging the battery, Design a variety of charging ways, accord ingto the type of battery, battery section number and the stat us of the battery to choose the best way ofcharging. Scientific way of charging, to prolong the service life of the battery., And can be addedwiththe charging unit, make many battery back charging time is shortened greatly.Positive and positive operation maintenance function: Give full consideration to the user spaceeffective utilization; Modular design and the positive maintenance, greatly shorten the troubleshoo tingof the machine time, improve the usability of UPS.Provide the ECO mode ,whole machine efficiency reached 93% ~ 94%, Reduce the UPS power loss;Can adapt to bad power grid environment.Excellent input frequency range make UPS can adapt todifferent power supply devices,IGBT High frequency intelligent rectifier inverter technology, The input power factor above 0.99, T heinput current harmonic as low as 3%; The output voltage current performance is more outstanding.Strong ability of overload: 110-125% of load can be normal operation for 10 minutes, 125-150% of loadcan be normal operation for 1 minute. And it have Output short circuit protection ability. Welcome your enquiryContact me :Shawn Zhang
Adres:
Floor 9, Building3, Jincheng Park, Dalang Street, Longhua District, Shenzhen, China
Soort bedrijf:
Fabrikant/fabriek
Zakelijk Bereik:
Bouw & Decoratie Materialen, Computer Producten, Consument Elektronica's, Elektrotechniek & Elektronica's, Industriële Apparaturen & Onderdelen, Instrumenten & Meters, Licht & Verlichting, Metallurgische, Mineralen & Energie, Produceren & Verwerken Machine, Veiligheid & Bescherming
Certificering Van Managementsysteem:
ISO 9001
Bedrijfsintroductie:
Meze-bedrijf werd opgericht in 1999, tot nu toe, heeft zich ontwikkeld tot een uitgebreide energievoorzieningsonderneming, producten omvatten: UPS ononderbroken stroomvoorziening, microcomputer non-contact elektronische AC geregelde voeding, EPS noodstroomvoorziening, etc. belangrijkste gamma: De financiële, overheid, onderzoeksinstituten, transport, ruimtevaart, Elektronica, medische diensten, enz. om te kunnen voldoen aan de mondiale elektronische en communicatie-industrie voor energieapparatuur is de vraag op de markt steeds krachtiger geworden, als gevolg van de behoefte aan ontwikkeling, werd shenzhen Meze Power Technology Co., Ltd opgericht in 2008 (gespecialiseerd in UPS-netfrequentie, geregelde stroomvoorziening, En transformator) in hetzelfde jaar registreerde Meze Electronics Co., Ltd. (Terminal Blocks, alle accessoires van PCB), in 2011, shenzhen Meze Mechanical and Electrical Co., Ltd. (SMT placement machine and accessories ).
Bestaand aantal werknemers: 180-180 werknemers, gebruikmakend van een oppervlakte van 3000 vierkante meter, heeft bedrijf de hoge technologie en rijke ervaring, Producten van bekende internationale merken van Europa, is toegewijd aan het bieden van klanten van het volledige assortiment van hoogwaardige hoogwaardige, stabiele bescherming van de stroomvoorziening. Met behulp van de internationale geavanceerde intelligente digitale UPS-voedingstechnologie en de meest geavanceerde precisiezuivering. De meest geavanceerde, geavanceerde, betrouwbaarste en de beste voedingsoplossingen bieden.