Gebruiksvoorwaarden: | Landgebruik |
---|---|
Gebruik: | Common Units |
Output Type: | AC Three Phase |
Koelmethode: | Water koelen |
Installatie Methode: | Vast |
Generator Type: | Dieselgenerator |
Leveranciers met geverifieerde zakelijke licenties
GLORIA 3PHASES LANDDYNAMO-GR225E | ||||||||
C0NTROL-SYSTEEM | APART ENTHOUSIAST VAN P.M.G. | |||||||
AVR | MX341 | |||||||
SPANNINGSREGELING | ±1.0% | |||||||
AANHOUDENDE KORTSLUITING | ZIE DE AFDALINGSKROMMEN VOOR KORTSLUITING | |||||||
REGELSYSTEEM | ZELF OPGEWONDEN | |||||||
A.V.R. | SX460 | |||||||
SPANNINGSREGELING | ±1.0% | |||||||
AANHOUDENDE KORTSLUITING | SERIE 4-REGELING HEEFT GEEN KORTSLUITSTROOM | |||||||
ISOLATIESYSTEEM | H | |||||||
PROTECEION | IP23 | |||||||
NOMINALE VERMOGENSFACTOR | 0.8 | |||||||
STATOR-WINDONG | DUBBELLAAGS CONCENTRISCH | |||||||
WINDENDE HOOGTE | TWEE DERDE | |||||||
WIKKELDRADEN | 12 | |||||||
STATOR WDG.WEERSTAND | 27 °C (0,1012 OHM) | |||||||
ROTOR WDG.WEERSTAND | 27 °C (0,7743 OHM) | |||||||
WEERSTAND VAN DE BEKRACHTIGINGSSTATOR | 27°C | |||||||
WEERSTAND VAN DE BEKRACHTIGINGSROTOR | 27°C (0,08080OHM) | |||||||
R.F.I.-ONDERDRUKKING | BS EN6000-6-2 en BS EN61000-6-4,VDE 1875G,VDE0875N.Raadpleeg de fabriek voor andere | |||||||
VERVORMING VAN DE GOLFVORM | <1.5% | |||||||
MAXIMALE OVERTOEREN | 2250 Rev/min. | |||||||
LAGER AANDRIJFZIJDE | 63122RZ | |||||||
LAGER NIET-AANDRIJFZIJDE | 63092RZ | |||||||
1 LAGER | 2 LAGER | |||||||
GEWICHT GENERATOR | 270 KG | 290 KG | ||||||
GEWICHT VAN DE GEWIKKELDE STATOR | 88 KG | 88 KG | ||||||
GEWICHT VAN DE GEWIKKELDE ROTOR | 92 KG | 89 KG | ||||||
WR² TRAAGHEID | 0.4999kgm² | 0.4682kgm² | ||||||
TRANSPORTGEWICHTEN in acrate | 290 KG | 315 KG | ||||||
GROOTTE VAN DE VERPAKKINGSKRAT | 108*66*94(CM) | 108*66*96(CM) | ||||||
50 Hz | 60 Hz | |||||||
TELEFOONSTORING | THF<2% | TIF<50 | ||||||
KOELLUCHT | 0.216 m³/sec 458 cfm | 0.281 m³/sec 595 cfm | ||||||
VOLTAGE SERIE STER | 380/220 | 400/231 | 415/240 | 440/254 | 416/240 | 440/254 | 460/266 | 480/277 |
SPANNING PARALLEL STER | 190/110 | 200/115 | 208/120 | 220/127 | 208/120 | 220/127 | 230/133 | 240/138 |
SPANNINGSBEREIK DELTA | 190/110 | 230/115 | 240/120 | 254/127 | 240/120 | 254/127 | 266/133 | 277/138 |
KVA-BASISCLASSIFICATIE VOOR REACTANTIEWAARDEN |
60 | 60 | 60 | 60 | 67.5 | 70 | 70 | 75 |
XdDIR.SNCHRONOUS | 2.48 | 2.24 | 2.08 | 1.39 | 3 | 2.78 | 2.64 | 2.5 |
X'D DIR.AS TRANSIËNT | 0.19 | 0.17 | 0.16 | 0.11 | 0.22 | 0.2 | 0.19 | 0.18 |
X„D DIR.AS SUBTRANSMISSIE | 0.13 | 0.12 | 0.11 | 0.07 | 0.15 | 0.14 | 0.13 | 0.13 |
XQ QUAD.AS REACTANTIE | 1.13 | 1.02 | 0.95 | 0.63 | 1.38 | 1.28 | 1.21 | 1.15 |
X„Q QUAD.AS SUBTRANSMISSIE | 0.14 | 0.13 | 0.12 | 0.08 | 0.14 | 0.13 | 0.12 | 0.12 |
XL -LEKKAGEREACTANTIE | 0.08 | 0.08 | 0.07 | 0.05 | 0.09 | 0.08 | 0.08 | 0.08 |
X2 NEGATIEVE SEQUENTIE | 0.13 | 0.12 | 0.11 | 0.07 | 0.14 | 0.13 | 0.12 | 0.12 |
X0 -NULSEQUENTIE | 0.11 | 0.1 | 0.09 | 0.06 | 0.09 | 0.08 | 0.08 | 0.08 |
REACTANCES ZIJN VERZADIGDE WAARDEN ZIJN PER EENHEID EN VOLACCE AANGEGEVEN | ||||||||
T'D TRANSIËNTE TIJD CONST. | 0.028 S | |||||||
T„D SUB-TRANSTIME CONST | 0.007 S | |||||||
T'do O.C.FIELDTIME CONST. | 0.7 S | |||||||
TA ANKER CONST. | 0.006 S | |||||||
VERHOUDING KORTSLUITING | 1/XD |