• High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
  • High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
  • High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
  • High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
  • High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches

High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches

type: hoogspanning
installatie: hoogspanning binnenshuis
bediening: handmatig
aardingsmodus: als specificatie
Transportpakket: Plywood Case
Specificatie: Three-column Disconnector

Contacteer leverancier

Diamant Lid Sinds 2018

Leveranciers met geverifieerde zakelijke licenties

Fabrikant/fabriek, Handelsbedrijf
  • Overzicht
  • Product Description
  • Our Factory
  • Our Exhibitions
  • Package& Transport
  • FAQ
Overzicht

Basis Informatie.

Model NR.
GN19-12ST-630A
Handelsmerk
JET
Oorsprong
China
Gs-Code
85352100

Beschrijving

 

Product Description
 

GN19-12, 12C series indoor high-voltage disconnect switches (hereinafter referred to as disconnect switches) are indoor devices with a rated voltage of 12kV, three-phase AC 60Hz, and are used for dividing and closing circuits when there is voltage and no load.

This series of isolation switch is three-pole type, consisting of base frame, rotating shaft, and lever, porcelain pillar insulator, gate knife and connection board. The rotating shaft is placed on the base frame, on which three pairs of levers are welded, and the levers are necked with the gate knife through the pull rod porcelain insulator. The shaft extends out of the bottom frame, and any section of it can be connected with the operating mechanism.

Structure and working principle

The conductive part of GN19-12/400, 630, 1000, 1250 type disconnect switch is fixed on the base by two pillar insulators for each phase. (GN19-12C/400, 630, 1000, 1250 type has one pillar insulator and one porcelain casing insulator.) The three phases are installed in parallel, and the conductive part consists of static contacts of contact knives and contact holders (or conductive rods). Each phase of the contact knife are connected to the middle of the tie insulator, tie insulator and installed on the base of the spindle connected. The spindle is connected to the connecting rod (user-provided) and CS6-1 type of moving mechanism through the handle. The connecting contact knife is composed of two slotted copper plates, which not only increases the heat dissipation area of the contact knife to lower the bottom temperature, but also improves the mechanical strength of the contact knife, so that the dynamic stability of the switch is improved. One end of the contact knife is mounted on the contact block (or on the conductive rod) by a bolt (car of Shaw). GN19-12/1000, 1250 in contact with the installation of magnetic locking plate, plus the purpose of the magnetic locking plate is that when a large short-circuit current to enhance the two groove contact knife between the| attraction. GN19-12/400, 630 disconnect switches have a small limit through current, so there is no need to add a magnetic locking plate.

Model meaning
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches

 

Use environmental conditions

1. The upper limit of ambient temperature +40ºC, the lower limit -l0ºC, Note: Allow storage and transportation at -25ºC
2. Altitude not more than 1000m
3. Relative humidity: daily average is not more than 95%, monthly average is not more than 90%
4. Water vapor pressure: the daily average is not more than 2.2 × 10-3Mpa, the monthly average is not more than 1.8 × 10-3Mpa
5. The surrounding air should be free from corrosive or combustible gases, water vapor and other obvious pollution.
6. No regular and violent vibration.
Note: Please consult with the manufacturer to solve the problem if it is not in line with the above conditions

Technical parameter

Model
Rated voltage  (kV)
Rated current 
(A)
Rated short-time withstand current
(kA/4s)
Rated peak withstand current
(kA)
GN19-12/400-12.5
12
400
12.5
31.5
GN19-12/630-20
12
630
20
50
GN19-12/1000-31.5
12
1000
31.5
80
GN19-12/1250-31.5
12
1250
31.5
80
GN19-12C/400-12.5
12
400
12.5
31.5
GN19-12C/630-20
12
630
20
50
GN19-12C/1000-31.5
12
1000
31.5
80
GN19-12C/1250-31.5
12
1250
31.5
80


High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
 

Our Factory
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
Our Exhibitions
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
Package& Transport
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches
FAQ

Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours
Q: Can l get a sample before the bulk order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us
Q:Do you accept product customization?
A: Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation
Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment.
Q: What is your Trade Terms?
A: We accept EXW, FOB, CIF, FCA, etc.
Q: What is your payment method?
A: We accept T/T, Western Union, Paypal, irrevocable L/C at sight, etc
Q: Do you inspect the finished products?
A: Yes, each step of production and finished products wil be came out inspection by Qc department before shipping. And we willprovide goods inspection reports for your reference before shipment
Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.
 

Stuur uw aanvraag naar deze leverancier

*van:
*naar:
*bericht:

Voer tussen 20 tot 4000 karakters.

Dit is niet wat je zoekt? Plaats Nu het Verzoek tot Scourcing

Zoek vergelijkbare producten op categorie

Startpagina leverancier Producten Isolatieschakelaar High Voltage Double Power Isolation Knife Switch Outdoor Disconnect Switches