Basis Informatie.
Type geleider
Solid & Stranded
Toepassing
Power Distribution Networks
Geleidermateriaal
Aluminum Alloy Conductor
Materiaal Vorm
Ronde Wire
Bereik van toepassing
Power Distribution Networks
Beschrijving
APPLICATION
YJLHV-Aluminum Alloy Conductor XLPE Insulated PVC Sheathed Power Cable
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 26/35KV
 

BASIC INFORMATION
1. Code Name 
YJLHV
2. Rated Voltage (Uo/U)
0.6/1KV
3. Cable Structure
Aluminum Alloy Conductor/XLPE Insulation/PVC Sheath
 
 
CONSTRUCTION
1. Conductor
Number of conductors:1,2,3,4,5
The conductors shall comply with the requirement given in IEC
2. Insulation
XLPE(Cross-linked Polyethylene) according to IEC
3. Sheath
PVC(Polyvinyl Chloride) according to IEC
 
 
 
CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
 
 
CHARACTERISTICS
1. Conductor temperature
Maximum conductor temperature in normal use: 90ºC
2. Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
3. Installation temperature
Ambient temperature under installation shall not be below 0ºC
4. Minimum bending radius
The bending radius of cable: (D-Diameter of cable) 
-------------------------------------≥7D

 
Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
 
Rated voltaged of cable applied in three phrase system are given in table


U | 
Um | 
Uo |

First class | 
Second class |

1 | 
1.2 | 
0.6 | 
0.6 |

3 | 
3.6 | 
1.8 | 
3.6 |

6 | 
7.2 | 
3.6 | 
6 |

10 | 
12 | 
6 | 
8.7 |

15 | 
17.5 | 
8.7 | 
12 |

20 | 
24 | 
12 | 
18 |

35 | 
42 | 
21 | 
26 |

Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
 
Production Range of cable


Type | 
No. of cores | 
Nominal Cross sectional area m2 |

Aluminum alloy conductor |

 
YJLHV
 | 
1* | 
4-800 |

2 | 
4-300 |

3 | 
4-630 |

4 | 
4-500 |

3+1 | 
4-630 |

5 | 
4-500 |

4+1 | 
4-500 |

3+2 | 
4-500 |

*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. |



 
DIMENSIONS-YJLHV-Table01


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

1×4 | 
0.7 | 
6.4 | 
58 |

1×6 | 
0.7 | 
7.0 | 
69 |

1×10 | 
0.7 | 
8.3 | 
94 |

1×16 | 
0.7 | 
9.3 | 
121 |

1×25 | 
0.9 | 
11.2 | 
175 |

1×35 | 
0.9 | 
12.4 | 
215 |

1×50* | 
1.0 | 
14.1 | 
278 |

1×70* | 
1.1 | 
16.1 | 
362 |

1×95* | 
1.1 | 
18.2 | 
468 |

1×120* | 
1.2 | 
18.7 | 
539 |

1×150* | 
1.4 | 
20.7 | 
658 |

1×185* | 
1.6 | 
22.6 | 
763 |

1×240* | 
1.7 | 
25.1 | 
952 |

1×300* | 
1.8 | 
27.5 | 
1172 |

1×400* | 
2.0 | 
30.9 | 
1478 |

1×500* | 
2.2 | 
34.5 | 
1861 |

1×630* | 
2.4 | 
38.5 | 
2299 |

1×800* | 
2.8 | 
46.0 | 
2937 |

*Compacted conductor

DIMENSIONS-YJLHV -Table 02


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

2×4 | 
0.7 | 
11.7 | 
115 |

2×6 | 
0.7 | 
12.7 | 
139 |

2×10 | 
0.7 | 
15.3 | 
195 |

2×16 | 
0.7 | 
17.4 | 
257 |

2×25 | 
0.9 | 
20.8 | 
269 |

2×35 | 
0.9 | 
23.1 | 
460 |

2×50* | 
1.0 | 
19.6 | 
478 |

2×70* | 
1.1 | 
22.6 | 
646 |

2×95* | 
1.1 | 
25.8 | 
849 |

2×120* | 
1.2 | 
28.2 | 
1042 |

2×150* | 
1.4 | 
40.2 | 
1520 |

2×185* | 
1.6 | 
44.2 | 
1800 |

2×240* | 
1.7 | 
49.6 | 
2329 |

2×300* | 
1.8 | 
54.8 | 
3076 |

*Compacted conductor
 
DIMENSIONS-YJLHV -Table 03


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

3×4 | 
0.7 | 
12.2 | 
135 |

3×6 | 
0.7 | 
13.4 | 
167 |

3×10 | 
0.7 | 
16.1 | 
238 |

3×16 | 
0.7 | 
18.4 | 
318 |

3×25 | 
0.9 | 
22.1 | 
463 |

3×35 | 
0.9 | 
24.6 | 
584 |

3×50* | 
1.0 | 
23.7 | 
677 |

3×70* | 
1.1 | 
27.9 | 
929 |

3×95* | 
1.1 | 
31.3 | 
1212 |

3×120* | 
1.2 | 
38.4 | 
1593 |

3×150* | 
1.4 | 
43.1 | 
2010 |

3×185* | 
1.6 | 
47.4 | 
2384 |

3×240* | 
1.7 | 
53.2 | 
3045 |

3×300* | 
1.8 | 
58.7 | 
3810 |

3×400* | 
2.0 | 
66.5 | 
4885 |

*Compacted conductor

DIMENSIONS-YJLHV -Table 04


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

4×4 | 
0.7 | 
13.2 | 
162 |

4×6 | 
0.7 | 
14.5 | 
201 |

4×10 | 
0.7 | 
17.6 | 
290 |

4×16 | 
0.7 | 
20.1 | 
392 |

4×25 | 
0.9 | 
24.3 | 
577 |

4×35 | 
0.9 | 
27.1 | 
731 |

4×50* | 
1.0 | 
26.2 | 
884 |

4×70* | 
1.1 | 
31.9 | 
1236 |

4×95* | 
1.1 | 
35.9 | 
1595 |

4×120* | 
1.2 | 
42.8 | 
2064 |

4×150* | 
1.4 | 
47.9 | 
2579 |

4×185* | 
1.6 | 
52.9 | 
3085 |

4×240* | 
1.7 | 
59.3 | 
3939 |

4×300* | 
1.8 | 
65.5 | 
4929 |

4×400* | 
2.0 | 
74.4 | 
6351 |

*Compacted conductor
 
DIMENSIONS-YJLHV -Table 05


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

5×4 | 
0.7 | 
14.2 | 
190 |

5×6 | 
0.7 | 
15.6 | 
237 |

5×10 | 
0.7 | 
19.1 | 
346 |

5×16 | 
0.7 | 
22.0 | 
470 |

5×25 | 
0.9 | 
26.6 | 
697 |

5×35 | 
0.9 | 
29.7 | 
887 |

5×50* | 
1.0 | 
32.6 | 
1132 |

5×70* | 
1.1 | 
37.8 | 
1536 |

5×95* | 
1.1 | 
42.8 | 
2053 |

5×120* | 
1.2 | 
47.3 | 
2541 |

5×150* | 
1.4 | 
53.1 | 
3201 |

5×185* | 
1.6 | 
58.6 | 
3692 |

5×240* | 
1.7 | 
65.8 | 
4882 |

5×300* | 
1.8 | 
72.7 | 
6108 |

5×400* | 
2.0 | 
82.7 | 
7899 |

*Compacted conductor

DIMENSIONS-YJLHV -Table 06


Nominal cross sectional area of conductor(mm²) | 
No.of cores | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

3x4+1x2.5 | 
3 | 
0.7 | 
12.9 | 
154 |

1 | 
0.7 |

3x6+1x4 | 
3 | 
0.7 | 
14.1 | 
191 |

1 | 
0.7 |

3x10+1x6 | 
3 | 
0.7 | 
16.8 | 
267 |

1 | 
0.7 |

3x16+1x10 | 
3 | 
0.7 | 
19.4 | 
365 |

1 | 
0.7 |

3x25+1x16 | 
3 | 
0.9 | 
23.2 | 
528 |

1 | 
0.7 |

3x35+1x16 | 
3 | 
0.9 | 
25.2 | 
642 |

1 | 
0.7 |

3x50+1x25 | 
3* | 
1.0 | 
26.0 | 
805 |

1 | 
0.9 |

3x70+1x35 | 
3* | 
1.1 | 
31.7 | 
1121 |

1 | 
0.9 |

3x95+1x50 | 
3* | 
1.1 | 
35.9 | 
1461 |

1 | 
1.0 |

3x120+1x70 | 
3* | 
1.2 | 
40.5 | 
1845 |

1 | 
1.1 |

3x150+1x70 | 
3* | 
1.4 | 
44.3 | 
2226 |

1 | 
1.1 |

3x185+1x95 | 
3* | 
1.6 | 
49.2 | 
2705 |

1 | 
1.1 |

3x240+1x120 | 
3* | 
1.7 | 
55.0 | 
2441 |

1 | 
1.2 |

3x300+1x150 | 
3* | 
1.8 | 
61.0 | 
4313 |

1 | 
1.4 |

3x400+1x185 | 
3* | 
2.0 | 
68.7 | 
5476 |

1 | 
1.6 |

*Compacted conductor

DIMENSIONS-YJLHV -Table 07


Nominal cross sectional area of conductor(mm²) | 
No.of cores | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

4x4+1x2.5 | 
4 | 
0.7 | 
14.0 | 
182 |

1 | 
0.7 |

4x6+1x4 | 
4 | 
0.7 | 
15.4 | 
228 |

1 | 
0.7 |

4x10+1x6 | 
4 | 
0.7 | 
18.4 | 
323 |

1 | 
0.7 |

4x16+1x10 | 
4 | 
0.7 | 
21.4 | 
445 |

1 | 
0.7 |

4x25+1x16 | 
4 | 
0.9 | 
25.7 | 
650 |

1 | 
0.7 |

4x35+1x16 | 
4 | 
0.9 | 
28.1 | 
800 |

1 | 
0.7 |

4x50+1x25 | 
4* | 
1.0 | 
31.5 | 
1039 |

1 | 
0.9 |

4x70+1x35 | 
4* | 
1.1 | 
36.1 | 
1403 |

1 | 
0.9 |

4x95+1x50 | 
4* | 
1.1 | 
40.8 | 
1857 |

1 | 
1.0 |

4x120+1x70 | 
4* | 
1.2 | 
45.5 | 
2346 |

1 | 
1.1 |

4x150+1x70 | 
4* | 
1.4 | 
50.0 | 
2852 |

1 | 
1.1 |

4x185+1x95 | 
4* | 
1.6 | 
55.5 | 
3451 |

1 | 
1.1 |

4x240+1x120 | 
4* | 
1.7 | 
62.1 | 
4392 |

1 | 
1.2 |

4x300+1x150 | 
4* | 
1.8 | 
68.8 | 
5501 |

1 | 
1.4 |

4x400+1x185 | 
4* | 
2.0 | 
77.8 | 
7032 |

1 | 
1.6 |

*Compacted conductor

DIMENSIONS-YJLHV -Table 08


Nominal cross sectional area of conductor(mm²) | 
No.of cores | 
Nominal insulation thickness(mm) | 
YJLHV |

Approx overall diameter(mm) | 
Cable weight max(kg/km) |

3x4+2x2.5 | 
3 | 
0.7 | 
13.5 | 
175 |

2 | 
0.7 |

3x6+2x4 | 
3 | 
0.7 | 
14.9 | 
218 |

2 | 
0.7 |

3x10+2x6 | 
3 | 
0.7 | 
17.5 | 
301 |

2 | 
0.7 |

3x16+2x10 | 
3 | 
0.7 | 
20.6 | 
419 |

2 | 
0.7 |

3x25+2x16 | 
3 | 
0.9 | 
23.9 | 
604 |

2 | 
0.7 |

3x35+2x16 | 
3 | 
0.9 | 
25.6 | 
715 |

2 | 
0.7 |

3x50+2x25 | 
3* | 
1.0 | 
29.5 | 
935 |

2 | 
0.9 |

3x70+2x35 | 
3* | 
1.1 | 
34.1 | 
1258 |

2 | 
0.9 |

3x95+2x50 | 
3* | 
1.1 | 
38.5 | 
1631 |

2 | 
1.0 |

3x120+2x70 | 
3* | 
1.2 | 
43.5 | 
2134 |

2 | 
1.1 |

3x150+2x70 | 
3* | 
1.4 | 
47.0 | 
2511 |

2 | 
1.1 |

3x185+2x95 | 
3* | 
1.6 | 
52.3 | 
3084 |

2 | 
1.1 |

3x240+2x120 | 
3* | 
1.7 | 
58.5 | 
3912 |

2 | 
1.2 |

3x300+2x150 | 
3* | 
1.8 | 
64.9 | 
4906 |

2 | 
1.4 |

3x400+2x185 | 
3* | 
2.0 | 
72.9 | 
6186 |


 
Product Data Of Cable


Nominal cross-sectional area of conductor(mm²) | 
Max.D.C resistance of conductor at 20ºC(Ω/km) |

Aluminum alloy |

4 | 
7.19 |

6 | 
4.48 |

10 | 
2.99 |

16 | 
1.85 |

25 | 
1.17 |

35 | 
0.843 |

50 | 
0.622 |

70 | 
0.430 |

95 | 
0.311 |

120 | 
0.246 |

150 | 
0.200 |

185 | 
0.159 |

240 | 
0.121 |

300 | 
0.0971 |

400 | 
0.0755 |

500 | 
0.0587 |

630 | 
0.0455 |

800 | 
0.0356 |

Power frequency A.C. Voltage test | 
Test voltage 3.5kV/5 min |



Current carrying capacity of cable
In the air


Conductor | 
Nominal Cross sectional area of conductor mm2 | 
Unarmored cable |

Single Core | 
Two Core | 
Three cores
&
Five cores |

 | 
 |

Aluminum Alloy Conductor | 
4 | 
32 | 
42 | 
34 | 
29 |

6 | 
42 | 
56 | 
45 | 
39 |

10 | 
55 | 
72 | 
58 | 
50 |

16 | 
71 | 
93 | 
75 | 
65 |

25 | 
94 | 
120 | 
100 | 
87 |

35 | 
115 | 
150 | 
120 | 
105 |

50 | 
140 | 
180 | 
150 | 
130 |

70 | 
180 | 
230 | 
190 | 
165 |

95 | 
220 | 
285 | 
235 | 
205 |

120 | 
260 | 
330 | 
275 | 
240 |

150 | 
300 | 
380 | 
315 | 
270 |

185 | 
350 | 
445 | 
365 | 
315 |

240 | 
414 | 
530 | 
415 | 
375 |

300 | 
485 | 
615 | 
480 | 
435 |

400 | 
570 | 
720 | 
560 | 
510 |

500 | 
670 | 
850 | 
650 | 
- |

630 | 
790 | 
1000 | 
- | 
- |

800 | 
920 | 
1180 | 
- | 
- |


Current carrying capacity of cable
In the ground


Conductor | 
Nominal Cross sectional area of conductor mm2 | 
Unarmored cable |

Single Core | 
Two Core | 
There cores
Five cores |

 | 
 |

Aluminum alloy
Conductor | 
4 | 
43 | 
47 | 
40 | 
40 |

6 | 
56 | 
60 | 
52 | 
52 |

10 | 
71 | 
75 | 
56 | 
56 |

16 | 
97 | 
97 | 
85 | 
85 |

25 | 
115 | 
125 | 
110 | 
110 |

35 | 
140 | 
150 | 
130 | 
130 |

50 | 
165 | 
175 | 
155 | 
160 |

70 | 
205 | 
215 | 
185 | 
195 |

95 | 
245 | 
260 | 
225 | 
235 |

120 | 
280 | 
295 | 
275 | 
165 |

150 | 
315 | 
335 | 
315 | 
300 |

185 | 
360 | 
380 | 
350 | 
340 |

240 | 
420 | 
445 | 
395 | 
395 |

300 | 
475 | 
505 | 
- | 
445 |

400 | 
545 | 
575 | 
- | 
510 |

500 | 
620 | 
665 | 
- | 
- |

630 | 
705 | 
760 | 
- | 
- |

800 | 
800 | 
875 | 
- | 
- |

 
Installation and Operation Condition of Cable
In the air
1.The distance between two adjacent cable' axle centers of single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm
2.Ambient air temperature:30ºC.
3.Max.continous operating temperature of conductor: 90ºC.

Current carrying rating factors for different ambient air temperature


Ambient air temperature | 
20ºC | 
25ºC | 
30ºC | 
35ºC | 
40ºC | 
45ºC |

Correction factor | 
1.09 | 
1.04 | 
1.00 | 
0.95 | 
0.90 | 
0.84 |



 
Directly in the ground
1.The single-core cables are installed separately.The distance between the cable
center is 2 times of the cable Diameter.
2.Soil temperature: 25ºC.
3.Max.continous operating temperature of
conductor: 90ºC.
4.Thermal resistivity of soil : 1.0 ºC. m/W
5.Depth of Direct-Buried:0.7m.

Current carrying rating factors for different soil temperature


Soil temperature | 
20ºC | 
25ºC | 
30ºC | 
35ºC | 
40ºC |

Correction factor | 
1.04 | 
1.0 | 
0.96 | 
0.92 | 
0.87 |
Adres:
Room1116, Floor 11, Hongxing Jiuzhou International Plaza, Xincheng Road, Yixing, Wuxi, Jiangsu, China
Soort bedrijf:
Fabrikant/fabriek, Handelsbedrijf
Zakelijk Bereik:
Chemische Stoffen, Diensten, Elektrotechniek & Elektronica's
Certificering Van Managementsysteem:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001
Bedrijfsintroductie:
Lonheo is opgericht in 2014 en heeft meer dan 30 jaar ervaring in kabel en is een uitstekende reputatie van onze medewerkende fabriek. We doen er alleen maar voor om ze tot toonaangevende kabelaannemers in de wereld te maken.
Lonheo is in staat om te streven naar de huidige concurrerende zakelijke omgeving door synergie te creëren en de middelen van alle partners te consolideren. Dit zorgt ervoor dat Lonheo operationeel en financieel sterk blijft.
Met dit strategische partnerschap is Lonheo in staat om onze klanten te helpen hun doelen te bereiken en hen meer diensten met toegevoegde waarde te bieden.
Ons bedrijf richt zich op de toevoer van kabels en draden en chemicaliën voor de behandeling van afvalwater.
Onze kenmerken Product:
===voedingskabels=== Ultra
High Voltage, voedingskabel, hoogspanningskabel, voedingskabel voor middelhoge spanning, voedingskabel voor laag voltage, LSZH-kabel (low smoke zero halogeenkabel), XLPE-kabel, voedingskabel voor AAAC (Aluminium Alloy Conductor), gepantserde kabel, SWA-kabel (stalen gepantserde kabel).
Stroomkabels worden voornamelijk gebruikt voor elektriciteitstransmissie- en distributiesystemen in de elektriciteitssector en de algemene industrie.
===draden en kabels voor elektrische apparatuur=== Rubber
-geïsoleerde kabel, mijnbouw, boor- en tunnelkabel, scheepskabel, nylon omhulde draad, kunststof geïsoleerde besturingskabel.
Kabels voor elektrische apparatuur worden voornamelijk gebruikt voor de toevoer en distributie van elektriciteit.
===Luchtkabel===
antennekabel, koperen gevlochten draad, ACSR-draden (Aluminium Conductor Steel Reinforced), AAAC-geleiders (Aluminium Alloy Conductor), AAC (Aluminium stranded Conductor).
Deze kabels worden voornamelijk gebruikt als bovengrondse elektriciteitsleidingen voor de overdracht van elektriciteit en de distributie van elektriciteit.
===Speciale kabels en draden===
Brandwerende kabel, hittebestendige kabel, knaagbestendige kabel/Termite-resistente kabel, waterdichte kabel, milieuvriendelijke gelijkstroomkabel, middenspanningskabel voor metrostation en lichtgewicht, windenergiekabel, nucleaire kabel van 1e-klasse, energiezuinige ACSR, UHV-ondersteunende en uitbreidende bovengrondse kabels, Flexibele brandbestendige kabel voor 0.6 kV.