MODEL | 
LPV -150-12 | 
LPV-150-15 | 
LPV -150-24 | 
LPV-150-36 | 
LPV-150-48 |

UITVOER | 
GELIJKSPANNING | 
12 V. | 
15 V. | 
24 VOLT | 
36 V. | 
48 V. |

NOMINALE STROOM | 
10 A. | 
8 A. | 
6, 3 BIS | 
4.2.2 | 
3.2A |

STROOMBEREIK | 
0 ~ 10 A. | 
0 ~ 8 A. | 
0 ~ 6, 3 A | 
0 ~ 4, 2A | 
0 ~ 3, 2A |

NOMINAAL VERMOGEN | 
120 W. | 
120 W. | 
151, 2 W. | 
151, 2 W. | 
153, 6 W. |

RIMPEL en GELUID (max. ) Opmerking. 2 | 
200 mVp-p | 
200 mVp-p | 
200 mVp-p | 
200 mVp-p | 
200 mVp-p |

OPMERKING OVER DE SPANNINGSTOLERANTIE. 3 | 
±5.0% |

LIJNREGELING | 
±1.0% |

BELASTINGSREGELING | 
±2.0% |

SETUP, RELISE TIME OPMERKING. 6 | 
LPV-150: 500 ms, 50 ms / 230 VAC 500 ms, 50 ms / 277 VAC; LPVL-150: 1500 ms, 50 ms / 115 VAC |

STOPTIJD (NORMAAL) | 
LPV-150: 18 ms/230 VAC 20 ms/277 VAC bij vollast; LPVL-150: 10 ms/115 VAC bij vollast |

INVOER | 
SPANNINGSBEREIK Opmerking. 4 | 
LPV-150: 180 ~ 305 VAC 254 ~ 431 VDC; LPVL-150: 90 ~ 132 VAC 254 ~ 370 VDC |

FREQUENTIEBEREIK | 
47 ~ 63 Hz |

EFFICIËNTIE (normaal) | 
87% | 
88% | 
89% | 
89% | 
90% |

AC-STROOM | 
LPV-150: 1, 7 A/230 VAC 1, 5 A/270 VAC; LPVL-150: 3, 0 A/115 VAC |

INSCHAKELSTROOM | 
Leeg type | 
KOUDE START 60A (twidth=900 μs gemeten bij 50% Ipeak) bij 230 VAC |

Type L. | 
KOUDE START 75A (twidth=900 μs gemeten bij 50% Ipeak) bij 115 VAC |

MAX. Aantal voedingseenheden | 
Leeg type | 
2 eenheden (stroomonderbreker van type B) / 3 eenheden (Stroomonderbreker van type C) bij 230 VAC |

Type L. | 
1 units (stroomonderbreker van type B) / 2 units (Stroomonderbreker van type C) bij 115 VAC |

LEKSTROOM | 
LPV-150: 0, 25 mA / 240 VAC LPVL-150: 0, 25 mA / 120 VAC |

BESCHERMING | 
OVERBELASTING | 
110 ~ 150% nominaal uitgangsvermogen |

Type bescherming: De modus "hiccup", herstelt automatisch na het verhelpen van de storing |

OVERSPANNING | 
13.5 ~ 18 V. | 
17 ~ 25 V. | 
27 ~ 35 V. | 
40 ~ 49 V. | 
52 ~ 63 V. |

Type beveiliging: Schakel de o/p-spanning uit, schakel de stroom weer in om de spanning te herstellen |

TE HOGE TEMPERATUUR | 
Schakel de o/p-spanning uit, herstelt automatisch nadat de temperatuur is daalt |

MILIEU | 
WERKTEMPERATUUR | 
-25 ~ +65 ºC (zie „derating Curve”) |

BEDRIJFSVOCHTIGHEID | 
20 ~ 90% relatieve luchtvochtigheid, niet-condenserend |

OPSLAGTEMPERATUUR, VOCHTIGHEID | 
-40 ~ +80ºC, 10 ~ 95% RV |

TEMP. COËFFICIËNT | 
±0.03%/ºC (0 ~ 40ºC voor LPV-150-12, 15 en LPVL-150-12, 24; 0~50ºC voor LPV-150-24, 36, 48) |

TRILLINGEN | 
10 ~ 500 Hz, 2 G 10 min. /1 cyclus, periode 60 min. Elk langs X-, Y-, Z-assen |

VEILIGHEID EN 
EMC | 
VEILIGHEID 
NORMEN | 
Leeg type | 
UL8750, CSA C22.2 No 250.13-12, UL879, CSA C22.2 No. 207-M89, IP67 goedgekeurd. Ontwerp: Zie EN60950-1 |

Type L. | 
UL8750(type„HL”), CSA C22.2 No 250.13-12, UL879, CSA C22.2 No. 207-M89, IP67 goedgekeurd |

WEERSTANDSSPANNING | 
I/P-O/P: 3 KVAC |

ISOLATIEWEERSTAND | 
I/P-O/P: > 100 OHM / 500 VDC / 25 ºC / 70% RELATIEVE LUCHTVOCHTIGHEID |

EMC-EMISSIE | 
Leeg type | 
Voldoet aan EN55022 (CISPR22) Klasse B, EN61000-3-2 Klasse A(≤80% belasting), EN61000-3-3 |

Type L. | 
Conformiteit met FCC deel 15 |

EMC-IMMUNITEIT | 
Leeg type | 
Voldoet aan EN61000-4-2, 3, 4, 5, 6, 8, 11; EN55024, licht industrieniveau, criteria A |

Type L. | 
Ontwerp: Zie IEC61000-4-2, 3, 4, 5, 6, 8, 11; Licht industrieniveau, criteria A. |

ANDERE | 
MTBF | 
703 kuur min. MIL-HDBK-217F (25 ºC) |

AFMETING | 
191*63*37, 5 MM (L*B*H) |

PAKKING | 
LPV-150: 0.74Kg; 20st/15.8Kg/0.95CUFT; LPVL-150: 0.85Kg; 20st/17Kg/0.95CUFT |

OPMERKING | 
1. Alle niet speciaal genoemde parameters worden gemeten bij een ingang van 230 VAC (115 VAC voor LPVL), nominale belasting en een omgevingstemperatuur van 25 ºC. 
2. Rimpel en ruis worden gemeten bij een bandbreedte van 20 MHz door gebruik te maken van een 12-inch getwiste paar-wire met een parallelle condensator van 0, 1uf en 47uf. 
3. Tolerantie: Omvat de ingestelde tolerantie, de lijnregeling en de belastingsregeling. 
4. Correctie kan nodig zijn bij een lage ingangsspanning. Controleer de statische kenmerken voor meer informatie. 
5. De voeding wordt beschouwd als een component die in combinatie met eindapparatuur zal worden gebruikt. Aangezien de EMC-prestaties worden beïnvloed door de 
De uiteindelijke fabrikanten van apparatuur moeten de EMC-richtlijn opnieuw kwalificeren voor de volledige installatie. 
6. De duur van de insteltijd wordt gemeten bij de eerste koude start. Het in- en UITSCHAKELEN van de voeding kan leiden tot een hogere insteltijd. 
7. De eenheid is mogelijk niet geschikt voor verlichtingstoepassingen in EU-landen. Neem contact op met de plaatselijke autoriteiten voor het mogelijke gebruik van het apparaat. 
8. Geschikt voor gebruik binnenshuis of buitenshuis zonder directe blootstelling aan zonlicht. |